Monday 8 July 2019

Meaford No.1 Inspection

Today volunteers Michael and Steve have done some survey work into one of our future projects, Meaford No.1 / RSH No.7683 which is next in the overhaul queue. Here, Michael is in the locos firebox carrying out some ultrasonic thickness testing on the inner firebox sidesheets

Doing the same on the smokebox tubeplate

Dome cover and dome plate off for more testing and to inspect the regulator valve and boiler tubes

Closer view of No.1's vertical slide type regulator valve. Shown in the video below, as the regulator handle is opened the smaller ports are opened through links on the regulator rod, this allows steam from the dome into the main steam pipes and through into the cylinders, the smaller ports are known as first valve or pilot valve. When the handle gets to roughly half way open the first valve slides start to push open the second valve, which is the bigger ports



No comments:

Post a Comment